Enerdrive DC 2 DC 40+amp Battery Charger/ MPPT Reg
Features
- Two totally independent DC Inputs for both engine and solar regulation charging one house battery bank output
- DC M6 screw terminals that will allow for large battery cable connection between all sources
- A dedicated Maximum Power Point (MPPT) solar regulator
- The same battery algorithms as included in our AC mains ePOWER battery charger. GEL, AGM, Flooded, Lithium and the ability to create a full custom profile
- Vehicle input allows for either 12 or 24v and a maximum solar input of 45V/800W
- 40A+ output up to 40+°C with thermo controlled fan cooling
- Fully programmable LCD display to show which source is charging the battery along with charger status, voltage and amperage
- Temperature sensor included with charger for more accurate battery charging
The Enerdrive ePOWER DC2DC+ Battery Charger is a fully automatic multistage, multi input battery charger with the ability to charge from either an alternator linked to a battery; or via solar power with the in built Maximum Power Point Tracking (MPPT) Solar Controller. With two inputs available, the main/house battery will be charged from either the engine while underway, or via the solar panels when stationary. The process to choose either engine or solar is fully automatic and both functions are controlled from within the unit itself without the need for external relays.
During normal operation the ePOWER DC2DC+ Battery Charger will do a full charge cycle to float stage on the house battery bank with ability to choose either GEL, AGM, Flooded, Custom Programmable or Lithium. Once float stage is reached the charger transitions to a power supply mode to support any on-board DC loads.
Specifications
DC2DC+ Battery Charger
Model | EN3DC40+ |
---|---|
Output Rating | |
Output Voltage | 12V Nominal (8.0V min) |
Output Current (Maximum) | 40A ~ 50A |
Output Power | 775W |
Charger DC Output (CH1): | |
Selectable Battery Type | Gel, AGM, Flooded, Lithium, Program |
Charger Voltage Range | 13.8V – 15.5V |
Float Voltage Range | 13.0V – 13.8V |
Charger Current (User Selectable) | 5/10/15/20/25/30/35/40/45/50A (default 40A) |
Equalize Voltage (Flooded Battery) | 15.5V |
Equalize Charging Current | 10% of Bulk Current Setting |
Charging Control | 2 stage / 3 stage selectable (Default 3 stage) |
DC Output Bank | Single |
Current draw from CH1 when not in use | < 50mA |
Battery Temperature Setting | Low/ Normal/ High (Battery Temperature Sensor Standard) |
Efficiency | 95% |
INPUT Rating (CH2 – MPPT Solar) | |
Input Voltage | 14.5 – 45VOC |
Maximum Input | ≤ 23V input, 500W (600W allowable) ≥37.5V-45V input, 750W (800W allowable) |
INPUT Rating (CH3 – Start/Alternator) | |
Input Voltage | 10.5 – 16VDC / 21 – 32VDC |
Dimensions | |
Height x Width x Depth | 242mm x 172mm x 74mm |
Unit Weight | 1.85 Kg |